By the way , Kindly Reminding:Please order "other accessories " when you order master bms and slave bms since
"other accessories " include precharge relay ,charge relay, discharge relay , ON-OFF switch relay,RS485-to USB Converter,
Pre-charging resistor ,Shunt , Fuse ,Photovoltaic anti-reverse diode , Diodes , Balancing wires ,Emergency Stop Button , Start Button, etc.
High voltage box need to be gounded ;Inverter need to be grounded;Battery case need to be grounded;
Master BMS Configuration + Monitoring of PC Softwarfe
Password:123456
Run Monitoring
RealTime Data
Historical Data
Alarm Data
Parameter Setting
System Setting
The lastest Version of BMS Bin File
Configuration for Different Inverters and flash Inverter protocals into Master BMS
(DEYE/GOODWE/ATESS/SOFAR/INVT_BD/PYLON/GROWATT/MEGAREVO/KOYOE)
Master BMS is used to configurate the charging cut-off / discharging cut-off /Over current cut-off / Balance starting /Inverter
Communication / Inverter charging cut-off / Invert discharging cut-off /Cell strings ,etc. Let me take BMS 48S for example ,
please see the following configuration
Attentions :for slave bms 32 S , you need to do setting in the pc software in this way : slave bms 32s = 2* slave bms 16s ; you need to enter 8 at Pack Nums+2 * 16 at Cell Nums + 2* 3 at Tempr Nums;
Entering 4 at pack Nums +32 at each Cell Nums +6 at Tempr Nums is not allowed ; BMS cannot work ;
Take 128S for example : you need to enter enter 8 * 16 at Cell Nums + 8* 3 at Tempr Nums;
Master BMS Configuration Via RS485 to USB - TOPBMS
Master BMS Configuration Via RS485 to USB - TOPBMS - V2.pdf
HV BMS Monitoring System
Before you set /calculate SOC , please enter password: AF123456;
How to get correct SOC now?
Set the design capacity / full capacitu / residual capacity in the pc software as below ;
regarding the residual capacity , please enter 1/2 full capacity
and then take a complet cycle of discharging and charging ; finally the SOC will be calibrated automatically
Wiring diagram of high voltage BMS with heating (REL5)/cooling(REL6)
Wiring diagram of high voltage BMS without heating (REL5)/cooling(REL6)
How to calibrate the current ?
Please adjust the FL CHG/FLDSG factors if charge current discharge current is not in line with actual current
HV BMS Montoring User Manual
HV BMS Monitoring System - TOPBMS-V2.pdf
Display Instruction of HV BMS- TOPBMS
Display Instruction of HV BMS.pdf
Cable for RS485 to USB
Driver Software (UT-8890)of Converter of RS485 to USB
Driver Software (UT-885/890/2003A/880/8801)of Converter of RS485 to USB
UT-885、890、2003A、880、8801 DRIVER.rar
Driver Software (CH340 for Win11)
Driver Software (CH340 for Win7,8,9,10)
CH348 Driver for win7 ,8 ,10.zip
you need to change the settings of converter via RS485 transmission cable ; if not , the converter cannot work properly
If you use slave bms 32s , please don't enter " 32" and "6";
you shall enter " 16 " and"3"+"16"and "3"
Master BMS Firmware Update :
you can flash the protocals /bin files into master bms
Battery capacity Settings in the BMS Monitoring Systerm Software
Slave BMS DIP CODE : each slave bms has one dip code ; the rule as following :